Independent Type Test Report

 

CPRI Test Report

 

 

Cable Type

Test Details

Test Report No.

Customer

 

3X70+1X35+1X10 SQ.MM. 1.9/3.3 kV Cable as per IS–1026/1984

cr/hv before and after short ckt test on conductor

CC–3114
DT.24.05.90

 
 

3X185 11 kV(E). A2XCEFY with one indoor
& one outdoor termination and one joint

PD/HV Before and after heating cycle. sample failed in pd

CC–3195
DT.08.10.90

 
 

A2XCEWY 3X150 SQ.MM. 6.6 kV (UE)

CR/PD/Power factor/vr/hv before and after short ckt test on conductor

CC-3342
DT.19.09.91
&
CC 3341
DT.19.06.91

 

 

A2XSEH 3X185 (AC)/25 (CU) 6/10 kV (E)

HV/CR/PD Before and after short ckt test on conductor

CC–3343
DT.27.06.91

 

2XCY 1X400 SQ.MM. 76/132 kV

Type test as per IEC 840 –1988 (including impulse test with print out)

CC–3365
DT.11.07.91

 

 

2XCY 1X400 SQ.MM. 76/132 kV

HV Test on sample 220 kv ac for 4 hours

CC–3366
DT.11.07.91

 

A2XCYWAY 1X400 SQ.MM. 19/33 kV (E)

Routine tests before and after short ckt test on conductor and short ckt test through armour and screen

CC–3368 a
&b
DT.22.07.91

 

 

APLYSTS 3X120 SQ.MM. 6.35/11 kV (E)

CR/HR before and after short ckt test on conductor

CC–3423
DT.30.09.91

 

*

A2XCEFY 3X240 SQ.MM.6.35/11 kV (E)

Electrical Type test. T.S.
& elong. hot set on insulation and routine tests before
& after short ckt test on conductor

CC–3449
DT.11.11.91

KSEB

APLYSTS 3X185 SQ.MM. 6.35/11 kV(E)

Type and Optional tests as per IS:692/1973

CC–3469 a
DT.01.01.92
& CC 3469 b
DT.02.01.92

PSEB

 

APLYSTS 3X240 SQ.MM. 19/33 kV (E)

Routine tests before and after short ckt test on conductor.

CC–3484
DT.02.01.92

 

 

A2XC2YWAY 1X240 SQ.MM. 38/66 kV (E)

Type tests as per IEC–840/1988 (impulse test with print out)

CC–3675 (a)
DT.02.09.92

GEB

*

A2XCEFY 3X300 SQ.MM. 12.7/22 kV (E)

Routine tests before and after short ckt test on conductor

CC–3816
DT.11.02.93

MSEB

*

2XCEFY 3X120 SQ.MM. 6.35/11 kV (E)

O.S., T.S. and elong. before and after U.V. exposure (DIN 53387)

CC–3851
DT.19.03.93

TCE / BANGLORE

*

YFAY 1X120 SQ.MM. 0.65/1.1 kV

O.S., T.S. and elong. before and after U.V. exposure (DIN 53387)

CC–3860 (B)
DT.02.04.93

TCE / BANGLORE

*

YFY 3X50 SQ.MM. 0.65/1.1 kV

O.S., T.S. and elong. before and after U.V. exposure (DIN 53387)

CC–3860 (A)
DT.02.04.93

TCE / BANGLORE

*

A2XCEFY 3X240 SQ.MM. 6.35/11 kV (E)

Routine tests before and after short ckt test on conductor

CC–3861
DT.06.06.93

NTPC / DELHI

A2XCEFY 3X185 SQ.MM. 6.35/11 kV (E)

Routine tests before and after short ckt test on conductor (tan delta as a function of voltage and capacitance)

CC–3988 (A+B)
DT.26.07.93

UPSEB

*

AWXCEFY 3X240 SQ.MM. 6.35/11 kV (E)

Electrical type test and acceptance tests and short ckt test on conductor. Routine test before and after short ckt test

3410 (A)
DT.13.09.91

KSEB

*

A2CEFAY 1X500 SQ.MM. 110 kV (E) (POLY AL TAPE)

1) Routine tests before and after short ckt test on conductor.
2) Longitudinal water tightness test.
3) Induced voltage test.

CC–4603
DT.12.06.95

KSEB

A2XCEFY 3X400 SQ.MM. 19/33 kV

CR.HV. PD before and after short ckt test on conductor

CC–4829
DT.22.12.95

MSEB

2XLyL 1X400 SQ.MM 64/110 kV

short time current test on lead sheath

SC/95/273/A
DT.25.01.96

*

2XAY 1X630 SQ.MM. 38/66 kV (E)

Short ckt test on corrugated aluminium sheath

SC–9811 A
DT.27.03.98

KEB

' * ' = Witnessed by Client

STJ = Straight Through Joint

ET = End Termination

 

CMRI Test Report

 

Cable Type

Test Details

Test Report No.

Customer

7M 3X25+1X25+1X16 - 640/1100 V

As per NCB 188/1978 + AMD. 5

E/T/7/2000
DT 23/5/2000

Done at CMRI

4X50 RR 1.1 kV

As per IS 9968 part I/1988

E/T/20/91
DT 7/11/91

Done at CMRI

RCgCR 3X120+3X70/3 6.35 kV

As per IS 9968 Part II/1981

E/T/21/91
DT 7/11/91

Done at CMRI

RCgCESR 3X70+3X35/3 6.6 kV (UE)

As per IS 9968 Part II/1981

E/T/7/92
DT 12/3/92

Done at CMRI

YWY 4X2.5 MM2 650/1100V MINIUM

As per IS I554 PART I/1988

E/T/13/99
DT 25/10/97

 

KEMA Test Report

 

Cable Type

Test Details

Test Report No.

Customer

2XCY1x630 RM/V 127/220 kV

As per IEC-840/1988

22192.00-HSC. 93-1078
DT 18/5/1993

KEMA, NETHE-RLAND

 

BVIS Test Report

 

Cable Type

Test Details

Test Report No.

Customer

A2XCEWY 3x95 6.35/11 kV

As per BS-6622/1991

8/8/97

BVIS

APLyYWY 4x95 600/1100 V

As per BS-6480/1988

2/23/98

BVIS

A2XFY 2x25 0.6/1 kV

As per IEC 502/1994

8/8/97

BVIS

2XCYWaY 1X500 18/30 kV

As per IEC 502/1994

9/7/98

BVIS

A2XCEWY 3x95 6/10 kV

As per IEC 502/1994

8/8/97

BVIS

 

ERDA Test Report

 

Cable Type

Test Details

Test Report No.

Customer

AYFY 3X400 1.1 kV

Tests for UV Exposure as per ASTM-4-53-1984 on outer sheath

1.02/11/1395
DT 28/3/95

A2XCEFY 11 kV

Tests for UV Exposure as per ASTM-4-53-1984 on outer sheath

1.02/11/1287
DT 7/4/93

A2XCEFY 3X185 11 kV

Tests for UV Exposure as per ASTM-4-53-1984 on outer sheath

1.02/11/951
DT 3/11/93

 

RITES Test Report

 

Cable Type

Test Details

Test Report No.

Customer

RR 1X25 - 1500 V

E14/01 PART II REV II-1993

5/19/00

RITES

RR 19X3 - 750 V

E14/01 PART I REV II-1993

3/28/00

RITES

RR 1X120 - 1500 V

E14/01 PART II REV II-1993

3/28/00

RITES

RR 1X270 - 1500 V

E14/01 PART II REV II-1993

3/28/00

RITES

RR 1X225 - 1500 V

E14/01 PART II REV II-1993

2/23/96

RITES

RR 1X2.5 - 750 V

E14/01 PART I REV II-1993

2/23/96

RITES

RR 1X120 - 1500 V

E14/01 PART II REV II-1993

2/17/95

RITES